Creator Electronics CR-M4102 Especificaciones Pagina 113

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 360
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 112
6 - 25
6.1.20 Current value change
CHGA Servomotor/virtual servomotor axis current value change control
(1) When the real mode is selected, the current value of the designated axis is
changed.
(2) When the virtual mode is selected, the current value of the designated virtual
servomotor is changed.
CHGA
AXIS 2, 50
<K 10>
Current value change control
• Axis used ............................................Axis 2
• Current value change address ...........50
CHGA-E Synchronous encoder axis current value change control
(1) The current value of the designated synchronous encoder axis is changed to the
designated address.
CHGA-B
AXIS 1, D10
<K 11>
Synchronous encoder axis current value change control
• Synchronous encoder No. ..............1
• Current value change address........Indirect designation
by D10, D11
CHGA-C Current value change within one rotation of cam shaft control
(1) When the CHGA-C command is executed, the current value within one rotation of
the designated cam shaft is changed to the designated address.
(2) In this case, the cam shaft may be rotating.
CHGA-C
AXIS 2, 0
<K 12>
Current value change within one rotation of cam
shaft control
• Output shaft No. ............................. 2
• Current value change address....... 0
Vista de pagina 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 359 360

Comentarios a estos manuales

Sin comentarios