Vista de pagina 154
9 - 15
9.5 Practice SFC programs
The sequence programs and SFC programs used for practice are listed below. Refer
to the following explanations for details on each program.
Normal execution
Start by sequence
program
Start by SFC program
•
Sequence program
•
[Initial setting] SFC program No.210: Automatic start
SFC program parameters
No. Program name
Automatic
start
END
operation
Number
of shifts
Execution timing
0 Real mode main No Normal
10 JOG operation No Normal
20 Zero point return No Normal
80 Servo program continuation No Normal
210 Initial setting Yes Normal
•
[JOG operation]
SFC program No.10
•
[Real mode main]
SFC program No.0
•
Virtual mode for
practice
•
[Zero point return]
SFC program No.20
•
[Servo program
continuous]
SFC program No. 80
Vista de pagina 154