11 - 37
[Virtual error detection] program No. 180
M2044=ON
Virtual error detection
When M4007 and M33 are turned
ON, M136 is turned ON.
(When the SFC program
"Push-button" is pressed, M316 is
turned ON, causing the switch to
turn on.)
SFC program No. 180
G1800 G1801
[Transition]
M2044 M4007*M33
F1800 F1401
[Operation control
step]
SET M316 RST M316
M33 : 2-second clock
M316 : Error detection signal
M4007 : Virtual servo error detection
[Cam change] program No. 190
Cam change
SFC program No. 190
When the X6 switch is
turned ON, one digit from
digital switch is stored in
D5030 (cam No.).
G1900
[Transition]
PX6
F1900
[Operation control
step]
DIN D5028,PX10
D5028 = D5028 & HF
D5030 = BIN(D5028)
M6 : Cam No. change command
D5030 : Cam No.