A - 33
(2) Execution timing
The current value is changed for a designated axis at the rising edge (OFF
ON) of the CHGA command.
(3) Operation error conditions
An operation error occurs in the following cases and the SVST command is not
executed.
(a) When the machine (set for reservation) is designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
(b) When the local machine is designated by object machine CPU head No.
input/output No. ÷ 16 [nl]
(c) When a CPU other than Q motion CPU is designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
(d) When the command is configured of devices other than usable device
(e) When 0 to 3DFH, 3E4H and following are designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
END END END END
CHGA command
executio
Completion of command
acceptance at motion CPU side
ON
Current value change processing
ON
ON: For abnormal
completion only
Sequence program
1-scan
ON
CHGA command
Command accept
flag
Start accept flag
(axis)
Current value change
Command start accept
completion device (D1+0)
Device of status display
for command start
accept completed (+1)